Find serial number P2000 G3 HP

Use telnet or serial cable to connect

xxx.xxx.xxx.xxx login: admin
Password:

HP StorageWorks MSA Storage P2000 G3 iSCSI
System Name: SANxxx01
System Location: xxxxxxxx
Version: TS240P004-02
# show enclosure-status
Chassis                          Vendor   Product ID       CPLD EMP A CH:ID  Rev      EMP B CH:ID  Rev      WWPN
  Status
—————————————————————————————————————————–
2S6249C294                       HP       SPS-CHASSIS      22         00:031 2018           01:031 2018     500c0ff015fa2e3c
  OK
—————————————————————————————————————————–
Type     #  Status    FRU P/N      FRU S/N              Add’l Data
——————————————————————————-
FAN      01 OK        592267-002   CN8245T302           —
FAN      02 OK        592267-002   CN8245T303           —
PSU      01 OK        592267-002   CN8245T302           —
PSU      02 OK        592267-002   CN8245T303           —
Temp     01 OK        BK829B       CN8243M044           temp=41 C

Find serial number P2000 G3 HP

Show configuration and status HP raid esxi 5.1

Use iso esxi 5.1  customized HP

~ # /opt/hp/hpacucli/bin/hpacucli
HP Array Configuration Utility CLI 9.40.12.0
Detecting Controllers…Done.
Type “help” for a list of supported commands.
Type “exit” to close the console.

=> ctrl all show config

Smart Array E200i in Slot 0 (Embedded)    (sn: QT7AMV7298     )

   array A (SAS, Unused Space: 0  MB)

      logicaldrive 1 (558.7 GB, RAID 5, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)

Show configuration and status HP raid esxi 5.1

rename volume group AIX

I need to rename appoggiovg volumegroup

root@paul:/#lsvg
hpsanvg
rootvg
oraexpvg
dati2vg
dati3vg
dati4vg
dati5vg
appoggiovg

Appoggiovg is create over hdisk7

I need:

varyoffvg appoggiovg
exportvg appoggiovg

root@paul:/#lspv
hdisk2          00c655c40fab3811                    rootvg          active
hdisk0          00c7662d78e1b21f                    hpsanvg         active
hdisk1          00c655c4d544cca6                    oraexpvg        active
hdisk3          00c655c444918136                    dati2vg         active
hdisk4          00c655c4db40e342                    dati3vg         active
hdisk5          00c655c428a07b90                    dati4vg         active
hdisk6          00c655c428a0de52                    dati5vg         active
hdisk7          00c655c4ae67c723                    None

root@paul:/#importvg -y dati6vg hdisk7

root@paul:/#lspv
hdisk2          00c655c40fab3811                    rootvg          active
hdisk0          00c7662d78e1b21f                    hpsanvg         active
hdisk1          00c655c4d544cca6                    oraexpvg        active
hdisk3          00c655c444918136                    dati2vg         active
hdisk4          00c655c4db40e342                    dati3vg         active
hdisk5          00c655c428a07b90                    dati4vg         active
hdisk6          00c655c428a0de52                    dati5vg         active
hdisk7          00c655c4ae67c723                    dati6vg         active

rename volume group AIX

Integrazione Command View 10.2 con HP SIM 7.2

Monitoraggio EVA 8100 con HP SIM, installazione HP COMMAND VIEW 10.2 e HP System Insight Manager sullo stesso server windows 2008 r2 standard

– Installare prima HP SIM  e poi COMMAND VIEW 10.2  per evitare conflitto di porte tcp

– Verificare post installazione il corretto uso delle porte  tcp WBEM/WMI e SMI-S  (il primo installato con HP SIM e il secondo con il command view)
C: netstat –anb >netstat.txt

TCP 0.0.0.0:5988 0.0.0.0:0 LISTENING 1712 [JavaWrapper.exe]
TCP 0.0.0.0:5989 0.0.0.0:0 LISTENING 460 [WMIServer.exe]
. . . . . . . . .
TCP 0.0.0.0:60000 0.0.0.0:0 LISTENING 1712 [JavaWrapper.exe]

Nel caso evidenziato  :

WBEM/WMI utilizzala porta 5989
SMI-S utilizza le porte 5988 e 60000

aggiungere a : C:Program FilesHPSystems Insight Managerconfig
identificationwbemportlist.xml le righe in BLUE

<?xml version=“1.0” encoding=“UTF-8”?>
<wbemportlist>
               <port id=“5989” protocol=“https”>
                    <cimnamespacelist>
                         <cimnamespace name=“root/cimv2”/>
                         <cimnamespace name=“vmware/esxv2”/>
                         <cimnamespace name=“root/hpq”/>
                   </cimnamespacelist>
                  <interopnamespacelist>
                         <interopnamespace name=“root/pg_interop”/>
                         <interopnamespace name=“root”/>
                         <interopnamespace name=“root/emulex”/>
                         <interopnamespace name=“root/qlogic”/>
                         <interopnamespace name=“root/ibm”/>
                         <interopnamespace name=“root/emc”/>
                         <interopnamespace name=“root/smis/current”/>
                         <interopnamespace name=“root/hitachi/dm51”/>
                         <interopnamespace name=“interop”/>
                         <interopnamespace name=“root/interop”/>
                         <interopnamespace name=“root/switch”/>
                         <interopnamespace name=“root/cimv2”/>
                   </interopnamespacelist>
              </port>
             <port id=“60000” protocol=“https”>
                   <interopnamespacelist>
                         <interopnamespace name=“interop”/>
                  </interopnamespacelist>
             </port>
</wbemportlist>

Salvare il file e e riavviare servizio hp sim
E rilanciare da HP SIM il discovery del server su cui sono installati i componenti command view e hp sim

Maggiori info  qua HP SIM and COMMAND VIEW whitepaper

Integrazione Command View 10.2 con HP SIM 7.2

Enable serial logging from ESXi 5.1

During installation

If an ESXi 5.1 host does not successfully install, serial line logging can be configured when booting the installer using advanced kernel boot-time parameters. This takes effect for the current boot, and does not persist across future reboots.
To enable serial-line logging during installation:

  1. At the Loading ESXi installer screen, press Shift+O.
  2. At the prompt, append the advanced option to specify a serial port after runweasel:

    > runweasel debugLogToSerial=1 logPort=com1

  3. Press Enter to boot.
  4. Logging starts after the first loading progress bar finishes.

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2032350

Enable serial logging from ESXi 5.1

Determining driver ESXi 5

~ # esxcfg-scsidevs -a

vmhba38 ahci              link-n/a  sata.vmhba38                            (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller
vmhba39 ahci              link-n/a  sata.vmhba39                            (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller
vmhba0  ahci              link-n/a  sata.vmhba0                             (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller
vmhba1  qla2xxx           link-n/a  fc.20000024ff0aa474:21000024ff0aa474    (0:17:0.0) QLogic Corp ISP2532-based 8Gb Fibre Channel to PCI Express HBA
vmhba2  megaraid_sas      link-n/a  unknown.vmhba2                          (0:22:0.0) LSI / Symbios Logic MegaRAID SAS Fusion Controller
vmhba3  qla2xxx           link-n/a  fc.20000024ff0aa479:21000024ff0aa479    (0:32:0.0) QLogic Corp ISP2532-based 8Gb Fibre Channel to PCI Express HBA
vmhba40 ahci              link-n/a  sata.vmhba40                            (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller
vmhba32 bnx2i             unbound   iscsi.vmhba32                           Broadcom iSCSI Adapter
vmhba33 bnx2i             unbound   iscsi.vmhba33                           Broadcom iSCSI Adapter
vmhba34 bnx2i             unbound   iscsi.vmhba34                           Broadcom iSCSI Adapter
vmhba35 bnx2i             unbound   iscsi.vmhba35                           Broadcom iSCSI Adapter
vmhba36 ahci              link-n/a  sata.vmhba36                            (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller
vmhba37 ahci              link-n/a  sata.vmhba37                            (0:0:31.2) Intel Corporation Patsburg 6 Port SATA AHCI Controller

~ # vmkload_mod -s qla2xxx | grep Version

 Version: Version 902.k1.1-9vmw, Build: 799733, Interface: 9.2 Built on: Aug  1 2012
~ #

Determining driver ESXi 5