Last summer i have needed to configure 3 cluster PowerHa 7.1.3.3.
After configuration i found this command to generate a HTML report whit all information.
clmgr view report cluster file=/tmp/xxxx.html type=html company_name=”My Company”
Last summer i have needed to configure 3 cluster PowerHa 7.1.3.3.
After configuration i found this command to generate a HTML report whit all information.
clmgr view report cluster file=/tmp/xxxx.html type=html company_name=”My Company”
9/01/2015 09:01:34 ANS0266I The dsmEndTxn vote is ABORT, so check the reason field.
09/01/2015 09:01:34 ANS0326E This node has exceeded its maximum number of mount points.
09/01/2015 09:01:39 ANS1004W Node has exceeded max tape mounts allowed. Operation for ‘xxxx’ will be tried again later.
On opt file i find:
VMMAXP=4
on definition of NODE on TSM server i found
MAXNUMMP=1
this is incorrect.
I need change the value for MAXNUMMP:
MAXNUMMP >= VMMAXP
After upgrade my vsphere infrastructure to 5.5 i have problem of disconnect network after reboot:
https://communities.vmware.com/thread/498472
Now i have change on my vm windows the network adapter type from e1000 to vmxnet3
I have used this step :
– Save IP Address configuration
– Shutdown VM
– Copy Mac Address
– Remove E1000 network adapter
– Add vmxnet3 network adapter and set manual mac address
– Boot VM
– For windows 2008 and older set devmgr_show_nonpresent_devices=1
– Remove, if present, the old network adapter
– Configure ip address…
Get-mVMHostCDPInfo.ps1 -VMHost esxhostname | ft -a
Find the script Get-mVMHostCDPInfo.ps1 in this site :
Last DAY i have needed upgrade my MDS9124 from 5.0.4(d) to 5.2.8(e).
When i started the upgrade i recaived this message:
disruptive upgrade
O my god!!!! is not possible.
I found the solution… i have resolved with reload the switch (this is siwtch is up from 5 years and the memory is 90% busy).
After reload the upgrade is Non-disruptive
verify :
getsebool httpd_can_sendmail
if httpd_can_sendmail is off.
use:
setsebool httpd_can_sendmail 1
permanent:
setsebool -P httpd_can_sendmail 1
I need upgrade switch mds9124 for compatibility with San Volume Controller 7.4
Now NX-OS on MDS switch is :
kickstart: version 5.0(4d)
system: version 5.0(4d)
Command for view NX-OS is “show ver”
After this i have checked free space on bootflash dir:
dir bootflash:
315 May 19 09:04:25 2010 MDS20100519015906567.lic
315 May 19 09:05:15 2010 MDS20100519020136847.lic
318 May 19 09:05:51 2010 MDS20100519020443144.lic
46080 Aug 17 21:36:20 2011 lost+found/
18832896 May 18 10:57:02 2010 m9100-s2ek9-kickstart-mz.4.2.5.bin
18788352 Aug 17 21:33:05 2011 m9100-s2ek9-kickstart-mz.5.0.4d.bin
52767390 May 18 11:03:06 2010 m9100-s2ek9-mz.4.2.5.bin
56800543 Aug 17 21:30:34 2011 m9100-s2ek9-mz.5.0.4d.bin
2064 Aug 17 21:41:19 2011 mts.log
Usage for bootflash://sup-local
160452608 bytes used
2519040 bytes free
162971648 bytes total
In this switch i have less free space. I need old version.
MDS-CP-02# del bootflash:m9100-s2ek9-kickstart-mz.4.2.5.bin
MDS-CP-02# del bootflash:m9100-s2ek9-mz.4.2.5.bin
Ok i am ready to load news fw in to bootflash dir i use tftp server:
copy tftp://10.1.1.207/m9100-s2ek9-kickstart-mz.5.2.8e.bin bootflash:m9100-s2ek9-kickstart-mz.5.2.8e.bin
copy tftp://10.x.x.x/m9100-s2ek9-mz.5.2.8e.bin bootflash:m9100-s2ek9-mz.5.2.8e.bin
I need replace Database on my installation MYSQL.
– Connect to DB
mysql -u <username> -p
– Show DB
SHOW DATABASES;
+——————–+
| Database |
+——————–+
| information_schema |
| mysql |
| website |
| wp-test |
| wpdb |
+——————–+
5 rows in set (0.00 sec)
– Drop Database
DROP DATABASE wpdb;
Query OK, 18 rows affected (0.01 sec)
-Recreate DB
create database wpdb;
Query OK, 1 row affected (0.00 sec)
– Import Database
mysql -u user -p wpdb < wp_xxxx2014.dmp
I use tftp server.
Use command line, connect with ssh client to MDS switch. In this case MDS9124.
MDS-TAPE-3S-01# copy running-config tftp:
Enter destination filename: [MDS-TAPE-3S-01-running-config]
Enter hostname for the tftp server: 10.55.0.33
Trying to connect to tftp server……
Connection to server Established. Copying Started…..
|
TFTP put operation was successful
Copy complete, now saving to disk (please wait)…
MDS-TAPE-3S-01#
In questi giorni VMWARE ha presentato la nuova piattaforma di virtualizzazione VSPHERE 6 e alcune piattaforme per gestione e implementazione dell’hybrid cloud.
Come si può immaginare oltre che, come avviene sempre con le nuove versioni, VMWARE con VSPHERE 6 ha spostato l’asticella verso l’alto relativamente alle risorse HW gestite:
Mentre altri aspetti interessanti sono il Fault tolerance su cui ha ampliato il supporto fino a 4 virtual cpu, il vmotion che adesso puo’ essere fatto tra virtual center e anche “long distance”